top of page

Prevent failures. Protect workers. Pass every audit.

Because unseen risks shouldn’t become unplanned disasters

Lumearis inspections identify and neutralize hazards before they trigger downtime, fines, or injuries. We help Quebec and Ontario industries identify, quantify, and prevent the electrical risks that lead to fires, downtime, fines, and injuries — with inspections and studies aligned to NFPA 70B / 70E.

7b4df895fed163311155e0a982a87176.jpg
pexels-cottonbro-9665357.jpg

NFPA 70B compliance, preventive safety, and measurable ROI

20 Industrial Electrical Risks We Help You Avoid

In industrial operations, one overlooked fault can cascade into catastrophic losses. CNESST audits, insurance claims, and unplanned outages all trace back to risks that could have been detected earlier.

Lumearis brings an FMEA mindset — detecting, rating, and neutralizing risks before they escalate.

Certified. Compliant. Trusted.

 

 

Every Lumearis inspection is backed by the certifications that regulators, insurers, and auditors recognize. We are the only provider in Quebec and Ontario delivering inspections aligned to NFPA 70B / NFPA 70E.

Download Our FMEA Analysis

Lumearis has conducted Failure Modes and Effects Analysis (FMEA) across multiple industrial sectors in Quebec and Ontario — from manufacturing and mining to energy and agriculture. The results reveal the Top 20 electrical risks most likely to trigger downtime, fires, fines, or injuries.

b88257371854f5c7073ff2190b49c721.jpg

Certified. Compliant. Trusted.

Every Lumearis inspection is backed by the certifications and standards that regulators, insurers, and auditors require. We are the only provider in Quebec and Ontario delivering inspections aligned with NFPA 70B / NFPA 70E (2023).

This is your Testimonial quote. Give your customers the stage to tell the world how great you are!

Frankie B.

This is your Testimonial quote. Give your customers the stage to tell the world how great you are!

Frankie B.

This is your Testimonial quote. Give your customers the stage to tell the world how great you are!

Frankie B.

This is your Testimonial quote. Give your customers the stage to tell the world how great you are!

Frankie B.

This is your Testimonial quote. Give your customers the stage to tell the world how great you are!

Jesse N.

This is your Testimonial quote. Give your customers the stage to tell the world how great you are!

Jamie L.

Group 23-2.png

ISO 50002 (Energy Audits & Monitoring)

Supports compliance with ISO 18434-1, ISO 18436-7, and ISO/IEC 17025 for precision testing, calibration, and condition monitoring.

Group 23.png

Infrared Training Center (ITC)

Ensuring inspections follow best-in-class international practices in thermal imaging and anomaly detection.

Group 23-5.png

           NFPA 70B / 70E           (2023)

These NFPA guidelines establish the requirements for thermographic inspections and electrical safety programs — ensuring compliance, reliability, and reduced risk.

Group 23-3.png


CSA Z462 / Z463

Ensures Lumearis services align with national compliance requirements recognized by regulators and insurers.

Group 23-7.png

CNESST (Quebec) / ESA (Ontario)

Our reports are audit-ready, ensuring businesses meet CNESST and ESA requirements for worker safety, maintenance practices, and insurance verification.

Group 23-7.png

Emploi Québec (C Licence – Licensed Journeyman Electricians)

This ensures clients receive services from qualified professionals who meet Quebec’s strict licensing requirements.

Process & Production Risks

  1. Hidden moisture ingress in control cabinets

  2. Overheated conductors from undersized wiring

  3. Repeated tripping of breakers leading to downtime

  4. Unverified single-line diagrams causing lockout/tagout errors

  5. Incomplete commissioning checks on new production lines

Equipment & Downtime Risks

  1. Transformer overload or insulation breakdown

  2. Motor bearing failures detected by thermal imbalance

  3. Overloaded or unbalanced circuits driving premature wear

  4. Harmonics and poor power quality damaging sensitive equipment

  5. Improperly rated protective devices (fuses, relays, breakers)

Fire & Safety Hazards

  1. Overheated breakers and fuses

  2. Loose or corroded electrical connections

  3. Arc flash hazards from improper PPE labeling

  4. Aging switchgear or panels without maintenance records

  5. Inadequate grounding leading to dangerous fault currents

Financial & Compliance Risks

  1. CNESST violations and insurance claim denials

  2. ESA (Ontario) deficiencies during safety inspections

  3. Lack of bilingual (French/English) labeling for compliance in Quebec

  4. Inefficient HVAC and building systems driving energy waste

  5. Equipment failures leading to production halts and multimillion-dollar losses

From Thermography to Complete Electrical Safety

How Lumearis Mitigates These Risks

From thermographic inspections to full engineering studies, Lumearis delivers audit-ready compliance with the speed, clarity, and cost-efficiency businesses need —across Quebec and Ontario.

Gemini_Generated_Image_crbm5xcrbm5xcrbm.png

2D Electrical CAD & Single-Line Diagrams

Clear, bilingual CAD drawings and SLDs for lockout/tagout and audits, compliant with CSA Z462, CNESST, and ESA.

Gemini_Generated_Image_qid26qid26qid26q.png

Building Thermography (incl. Panels)
(NFPA 70B)

FLIR-certified thermal scans detect heat loss, leaks, and panel hotspots, aligned with NFPA 70B for preventive maintenance.

Gemini_Generated_Image_qid26qid26qid26q (4).png

Drone
Thermography

Aerial thermal inspections to detect heat loss, moisture, and electrical hotspots in hard-to-reach areas. Reports are NFPA 70B / CSA Z463 compliant and audit-ready.

Gemini_Generated_Image_qid26qid26qid26q (2).png

Electrical Infrastructure Thermography

We inspect switchgear, transformers, and distribution systems to catch overheating and faults early, per NFPA 70B / CSA Z463.

Gemini_Generated_Image_qid26qid26qid26q (3).png

Arc Flash Study (CSA Z462 / NFPA 70E)

Full arc flash hazard analysis with PPE labeling and bilingual reports, compliant with CSA Z462 / NFPA 70E and CNESST/ESA.

Gemini_Generated_Image_fovraxfovraxfovr.png

Short-Circuit Study

We model your system to confirm equipment can safely withstand fault currents, ensuring CSA C22.1 code compliance.

Gemini_Generated_Image_8de9tt8de9tt8de9.png

Power Quality Study (Harmonics / Flicker / Unbalance)

We measure harmonics, flicker, and unbalance with Fluke analyzers, ensuring compliance with IEEE 519 and CSA standards.

Gemini_Generated_Image_io1gbeio1gbeio1g.png

Grounding / Step & Touch Potential Study

Studies of step and touch voltages to prevent shock hazards, aligned with IEEE 80, CSA C22.3, and NFPA 70E

Electrical safety solutions built for every industry we power.

From manufacturing plants to data centers, Lumearis helps industries in Quebec and Ontario prevent downtime, reduce energy waste, and stay compliant with NFPA 70B / 70E, CSA, CNESST, and ESA standards. Whatever your sector, our inspections and studies are audit-ready, insurer-recognized, and sustainability-driven.

Energy & Utilities

Hydro, renewable (wind/solar), power distribution, substations

Manufacturing

Automotive, aerospace, food & beverage, pulp & paper, pharmaceuticals, heavy equipment

Oil & Gas / Petrochemicals

Refineries, storage terminals, processing facilities

Agriculture & Agri-Food

Dairy, poultry, crop storage, food processing

Data Centers

Colocation, enterprise, and hyperscale facilities

ROI & Business Value

Every inspection is an investment with measurable returns.

How Lumearis creates ROI

  • Failure prevention: NFPA 70B inspections prevent 85% of equipment failures.

  • Maintenance savings: Clients report a 30% reduction in unplanned maintenance.

  • Financial protection: Preventing a single arc flash event can avoid >$500,000 in liability and lost productivity.

  • Insurance leverage: Audit-ready reports strengthen your insurer negotiations and reduce premium risk scores.

From office towers to retail chains, Lumearis keeps commercial spaces safe, compliant, and efficient.

We specialize in electrical inspections and studies across a wide range of commercial properties in Quebec and Ontario, delivering NFPA 70B / 70E–aligned compliance, insurer-ready reporting, and measurable ROI.

Retail & Shopping
Centers

Prevent tenant disruptions, protect brand reputation, reduce energy waste

Office Towers & Multi-Tenant Complexes

Ensure CNESST/ESA compliance, protect tenants, streamline renovations

Hospitality (Hotels, Restaurants, Convention Centers)

Reduce liability, maintain uptime for guests, pass insurance audits

Distribution & Logistics Facilities

Protect operations from downtime, lower energy costs, meet insurer demands

Mixed-Use Developments

Simplify compliance across property classes, provide bilingual reporting for regulators and insurers

Schedule My Industrial Risk Assessment

See which of the 20 critical risks your facility is carrying today.

Sector
Required Services
lumearis.png

Sustainability & Environmental Impact

Electrical safety drives energy efficiency and carbon reduction.

In Quebec and Ontario, industrial leaders are under increasing pressure to reduce greenhouse gas (GHG) emissions, improve energy efficiency, and demonstrate compliance with frameworks like Quebec’s Plan pour une économie verte 2030 and Ontario’s Energy Efficiency Framework.

  • Energy efficiency gains: Thermographic inspections reveal overloaded circuits, failing motors, and insulation gaps — cutting wasted energy by up to 30%.

  • GHG reduction: Lower energy demand directly reduces Scope 2 emissions, supporting Canada’s net-zero 2050 commitments.

  • Asset life extension: Preventive maintenance avoids premature replacements, reducing e-waste and embedded carbon.

  • Policy alignment: Reporting structured for ISO 50002, CNESST preventive requirements, and ESA energy programs.

Straight Answers. Sparkless Compliance.

 

198 Grande Cote Ouest ,

Lanoraie, j0k1e0,

Quebec, Canada

Call  +1 (438) 231-1382

bottom of page